IQTS-RS232
IQsocket

IQTS-RS232

RS232 watchdog socket for serial control and automatic power restart.

Active ProductIn Stock
ProducerIQtronic technologies Europe s.r.o.
Price on request
Socket Type
Ordering code

IQTS-RS232-E

Availability

In stock

Overview

IQTS-RS232 — RS232 watchdog socket for serial control and automatic power restart.

IQTS-RS232 is a serial controlled power outlet and RS232 watchdog socket. Switch power with AT commands or automatically restart stalled equipment.

IQTS-RS232 is an IQsocket smart power socket controlled through an RS232 serial interface. AT commands switch or restart connected equipment. When the watchdog is enabled, the connected device sends periodic serial data; if data stop for two minutes, the socket interrupts power for ten seconds. Monitoring begins six minutes after power-up. A supplied crossover cable connects the DB9 interface to a PC. Choose a regional socket version suitable for your installation.

Socket Versions

Available socket versions

Select the required socket version in the product options. Available versions are shown below.

Base ordering code: IQTS-RS232-X

French (Type E) socket

French (Type E)

IQTS-RS232-E

Schuko (Type F) socket

Schuko (Type F)

IQTS-RS232-F

Swiss (Type J) socket

Swiss (Type J)

IQTS-RS232-J

UK (Type G) socket

UK (Type G)

IQTS-RS232-G

Israel (Type H) socket

Israel (Type H)

IQTS-RS232-H

USA (Type B) socket

USA (Type B)

IQTS-RS232-B

Italian (Type L) socket

Italian (Type L)

IQTS-RS232-L

Availability may vary by version. Please confirm your selected socket type before ordering.

Applications

Real-world use cases

Server watchdog
A server or industrial PC sends periodic data over RS232. If its software freezes and data stop, the socket power cycles the connected equipment.
Unattended control system
An embedded controller sends a serial keep-alive so the watchdog can restart it after a software lockup at an unattended site.
Serial power control
A host sends AT commands to turn connected equipment on or off, or to request a ten-second power reset.
Test bench recovery
Use the serial interface to restart a compatible instrument or controller during automated testing when the host detects a fault.
Technical Specifications

Specifications

Full electrical and mechanical data is available in the datasheet.

InterfaceRS232, DB9 male; supplied crossover cable
ControlAT commands for power on, off and 10-second reset
WatchdogStarts after 6 minutes; restarts after 2 minutes without serial data
Serial settings9600 8N1 by default; 19200, 57600 and 115200 baud selectable
Supply100–230 V AC, 50–60 Hz
Output loadUp to 16 A resistive or 15 A capacitive, depending on socket type
EnvironmentIndoor use, IP40; −20 to +50 °C